MD-LIMS — Molecular Diagnostics Laboratory Information Management System
Radhey Radhey Enterprises, #2, Shree Radhey Complex, Science Market, Ambala Cantt, Haryana 133001 · 0171 4525101 · +91 87084 10052 · software@labscope.co.in
GSTIN 06ABBFR4715K1Z5 · Udyam UDYAM-HR-01-0032974 (Micro, Partnership) · GeM Seller ID U3N2240012054436 · Drug Licence (MD-42) HR/AMB/MD42/2024/000014
Capability list
Capabilities
What MD-LIMS does, grouped by area of the laboratory’s work. Each item has a reference number that can be quoted in correspondence and in a compliance statement.
SM Sample management
- SM-01Sample reception with a unique accession number and barcode. Acceptance or rejection is recorded with a reason.
- SM-02Aliquots and derivatives are linked to their parent sample.
- SM-03Storage is recorded down to freezer, shelf, rack, box and position, with location history and thaw count. Removing a sample from storage requires a recorded reason.
- SM-04The complete chain of custody of a sample can be read on one screen.
TR Testing and results
- TR-01Methods are configured per laboratory, with versions. Each method defines its result fields, units and decimals.
- TR-02Laboratory-defined calculations. The software computes derived values, such as delta Ct, from the fields entered, and keeps the inputs.
- TR-03Reference ranges and critical values are flagged at entry.
- TR-04Runs and plate layouts. The instrument and the reagent lots used are recorded against the run.
- TR-05Results are reviewed by a person other than the one who entered them, who accepts, rejects or asks for a repeat, with a reason.
QC Quality control
- QC-01Westgard multi-rule QC: 1-3s, 1-2s, 2-2s, R-4s, 4-1s and 10-x.
- QC-02A failed control holds the run automatically. Only an authorised person may release the hold, and the reason is recorded.
- QC-03Levey-Jennings charts with the ±1, ±2 and ±3 SD bands.
- QC-04Turnaround time targets per method, with a list of breaches.
RS Reporting and signatures
- RS-01Multi-level review and approval, configured to the institute’s own policy.
- RS-02Every signature requires the password to be entered again at the moment of signing, and is bound to a SHA-256 hash of exactly the content signed.
- RS-03Any change after signature produces a new version with its own hash. Nothing is overwritten and nothing is deleted.
- RS-04Printable reports, and secure, time-limited, audited delivery links.
- RS-05Report formats are built to the institute’s own format during implementation.
IN Instruments
- IN-01Instrument register with calibration and preventive-maintenance schedules. An overdue instrument can be blocked from use.
- IN-02Instrument interfacing through a gateway that speaks ASTM E1381/E1394 and HL7 v2 over MLLP, and collects result files from a watch folder or network storage.
- IN-03The driver for each instrument is built from that instrument’s own output files during the site survey. Drivers do not exist in advance for every instrument.
- IN-04Temperature monitoring of freezers and cold rooms through sensor integration, configured at site.
RG Reagents and stock
- RG-01Reagent lots are recorded with expiry. A lot arrives in quarantine and cannot be consumed until it is released.
- RG-02Alerts for expiring, expired and low stock.
- RG-03Consumption is traced to the results it produced, so a recalled lot can be followed.
PA People and access
- PA-01Roles and permissions per module and per method.
- PA-02Authorisation per method is enforced at entry, review and signature. A person not authorised for a method cannot run it.
- PA-03Training and competence records, with competence that lapses.
- PA-04Proxy login records both people. There is no signing under proxy.
- PA-05The system administrator holds no laboratory permission and cannot read patient results.
RD Referring departments
- RD-01A portal where a referring ward or department books tests and reads only its own released reports.
DP Data protection
- DP-01PostgreSQL with row-level security enforced by the database itself, not by query filters. The account the application connects with owns nothing and cannot bypass it.
- DP-02An append-only, hash-chained audit trail of every action.
- DP-03A nightly backup that restores itself into a scratch database and re-verifies the audit chain before the copy is kept.
This list describes the software as supplied. Institute-specific report formats, instrument drivers and temperature sensors are built or configured during implementation, as described on the Deployment page.